Hot-aisle/cold-aisle containment takes hold

By Mark Fontecchio, News Writer, SearchDataCenter.com
01 Oct 2009 | SearchDataCenter.in

Digg This!    StumbleUpon Toolbar StumbleUpon    Bookmark with Delicious Del.icio.us   

Hot-cold aisle containment has quickly become a big factor in data center design, possibly because it can create significant energy savings, according to a recent SearchDataCenter.com survey.

For more on the recent Data Center Decisions survey:
Budgets flatten, clampdown on costs

Blade server popularity cools

Linux fans see opportunity in Windows 7 changeover
The survey also found that data center and IT managers are much more aware of their power consumption than they were just a year ago. Last year, 36% said they didn't know how much their data center power bill was. That number has decreased to 28% this year. Further, the number of people whose business unit pays the power bill jumped from 37% to 53%.

And power consumption continues to grow. Almost half said their power bills increased this year over last, with about one-fifth putting that increase at more than 10%.

Hot-cold aisle containment gains traction
Hot-cold aisle containment is the practice of sealing a data center's hot aisle and/or cold aisle to better control airflow and prevent the mixing of hot and cold air. Such mixing wastes cooling energy. Almost half the survey participants said they had either implemented hot-cold aisle containment or planned to do so this year.

we had to carefully balance air going in from air going out.
Tim Happychuk
IT director, Quebecor

Last year's survey didn't ask about the practice of hot-aisle and cold-aisle containment. Some companies fashion their own homegrown systems by installing thick strips of plastic – similar to those found in meat lockers – from the ceiling to the top of racks. Others buy custom-made systems from vendors such as Wright Line, Liebert and APC. For those survey respondents who have done containment, cold-aisle containment was the most popular (54%) followed by hot-aisle containment, and then ducted or plenum systems.

Canadian media company Quebecor uses both hot- and cold-aisle containment. Because its data center has only one row of racks, IT director Timothy Happychuk bisected the room to contain both aisles. Cool air from the outside is used to cool servers, and hot air exhausts out the back of the room, then piped into adjacent offices to warm them in the winter.

"Because of what we're doing in our data center environment, we had to carefully balance air going in from air going out," Happychuk said. "It's been working extremely well for us."

Dean Nelson, a data center director at eBay Inc., is also a proponent of hot-cold aisle containment. "Everybody is tuning right now for air, and they should be because their environments are air-cooled. They should make that as brutally efficient as possible," he said.

Data centers haven't warmed to liquid cooling
Many data centers pros hesitate to consider liquid cooling, a solution that could save them big bucks. Enthusiasm for that technology has decreased in the past year, however impossible it may seem. Respondents who said they would never use liquid cooling rose from 63% to 68% year over year, and fewer people are willing to even try it. Nelson said that's too bad.

"It's a phobia that doesn't have legs," he said. "The history is the IBM mainframes were liquid-cooled. We should be coming full circle here. This is just good engineering. It's just about controlling the water and having good design, such as isolation valves." Finally, survey participants indicated that APC continues to gain market share on Liebert on both power and cooling devices in the data center. APC's share for UPS systems increased from 59% to 64% this year, while its share for air conditioners jumped from 34% to 38%. Liebert's share dropped in both categories.

ABOUT SURVEY METHODOLOGY AND RESPONDENTS
Between June and September of 2009, SearchDataCenter.com conducted the Data Center Decisions 2009 Purchasing Intentions Survey. Subscribers were contacted by email and invited to participate. For this survey, we had a total of 920 respondents. The respondents identify themselves as IT managers, IT administrators, data center facility managers and IT executives. Respondents were primarily U.S.-based (43%), but the survey also included participants from Europe, Asia, Africa and the Middle East. More than half of respondents' organizations employ more than 1,000 workers, and more than 25% of the companies have more than 10,000 employees. Thank you to everyone who participated in this survey. Follow this link to the 2008 data center purchasing intentions survey.

Back to survey overview.

Let us know what you think about the story; email Mark Fontecchio, News Writer. Also, check out our blogs: Data Center Facilities Pro, Mainframe Propeller Head, and Server Farming.



Tags: Data center power and coolingGreen data center technology and best practicesData Center Operations and Design TipsVIEW ALL TAGS

Digg This!    StumbleUpon Toolbar StumbleUpon    Bookmark with Delicious Del.icio.us   



RELATED CONTENT
Data center power and cooling
Disaster recovery, power and cooling secrets from Airtel data centers
Data center power management at forefront of IT agenda
Data center power and cooling revamp success story at CRIS
Data center power and cooling strategies that insure IFFCO TOKIO
Data center site selection dilemmas? Read this
Green IT: How far is the Indian corporate ready to go?
Free cooling: Is it a viable option for Indian enterprises?
Five tips for N+1 uninterruptible power supply (UPS) design
Hot aisle - cold aisle design best practices for data centers
Data center cabling - Placing and design best practices

Green data center technology and best practices
Data center power management at forefront of IT agenda
Data center planning considerations for high availability
Server virtualization: Bilcare's hidden business plan aid
Data center power and cooling revamp success story at CRIS
Data center power and cooling strategies that insure IFFCO TOKIO
Server virtualization eliminates pain-points at Apeejay Surrendra
How server virtualization helps Perfetti save and go green
Green IT: How far is the Indian corporate ready to go?
Server virtualization: India Inc.'s top data center priority for 2010
I/O Virtualisation: green, flexible and virtual

Data Center Operations and Design Tips
Disaster recovery, power and cooling secrets from Airtel data centers
Data center planning considerations for high availability
How to determine the appropriate failover disaster recovery site: hot, cold or warm
Cloud storage's missing link
Data center power and cooling revamp success story at CRIS
Disaster recovery checklist: What you need in your DR budget
Data center power and cooling strategies that insure IFFCO TOKIO
Disaster recovery boosts customer service ops at Punjab National Bank
Using information lifecycle management for mainframe disaster recovery
Disaster recovery streamlines business at Jindal Steel

RELATED RESOURCES
2020software.com, trial software downloads for accounting software, ERP software, CRM software and business software systems
Search Bitpipe.com for the latest white papers and business webcasts
Whatis.com, the online computer dictionary

HomeNewsTopicsITKnowledge ExchangeTipsMultimediaWhite Papers
About Us  |  Contact Us  |  For Advertisers  |  For Business Partners  |  Site Index  |  RSS
SEARCH 
TechTarget provides technology professionals with the information they need to perform their jobs - from developing strategy, to making cost-effective purchase decisions and managing their organizations' technology projects - with its network of technology-specific websites, events and online magazines.

TechTarget Corporate Web Site  |  Media Kits  |  Site Map




All Rights Reserved, Copyright 2009 - 2010, TechTarget | Read our Privacy Policy
  TechTarget - The IT Media ROI Experts